Drake TR-4 'Blue' Filters removed
Filters from Bottom of TR-4 |
Filters removed from radio |
Measurement of Tedford SSB 9M 2100 U
Model 7970 Crystal Filter from TR-4
(the working filter)
Test conditions
Heathkit IG-102 set to read 20 over
Receiver FT-1000MkV
Rx F was set and Signal Gen was tuned for max meter reading on various F's
9.006.00 less than S1
9.002.00 less than S1
9.001.00 S8
9.00.00 S9
8.999.00 10 OVER
8.998.75 15 over
8.998.00 15 over
8.997.00 10 over
8.996.00 10 over
8.995.00 S9
8.994.00 S2
NO FILTER 20 OVER