Wednesday, April 6, 2011

Drake TR-4 Crystal Filters


Drake TR-4 'Blue' Filters removed

Filters from Bottom of TR-4

Filters removed from radio

Measurement of Tedford SSB 9M 2100 U
Model 7970 Crystal Filter from TR-4
(the working filter)

Test conditions 
Heathkit IG-102 set to read 20 over 
Receiver FT-1000MkV

Rx F was set and Signal Gen was tuned for max meter reading on various F's


9.006.00   less than S1
9.002.00   less than S1
9.001.00   S8
9.00.00    S9
8.999.00   10 OVER
8.998.75   15 over
8.998.00   15 over
8.997.00   10 over
8.996.00   10 over
8.995.00   S9
8.994.00   S2

NO FILTER 20 OVER